27
MODEL IDENTIFICATION
1 Code for external mount Jupiter
®
200
2
0
0 0 M
complete code for JUPITER
®
200: external mount model
APPROVALS AND HOUSING (consult factory for FM/CSA approvals)
BASIC MODEL NUMBER
0
2 4 Magnetostrictive transmitter with standard HART
®
electronics for level or interface
2 6 Magnetostrictive transmitter with SIL enhanced HART
®
electronics for level or interface
2 7 Magnetostrictive transmitter with standard HART
®
electronics for level and interface
➀
MATERIALS OF CONSTRUCTION
E 1 Top mount construction - 316/316L (1.4401/1.4404) max +120 °C (+250 °F)
F 1 Top mount offset construction - 316/316L (1.4401/1.4404) max +120 °C (+250 °F)
H 1 Bottom mount offset construction - 316/316L (1.4401/1.4404) max +120 °C (+250 °F)
G 7 Top mount HT offset construction - 316/316L (1.4401/1.4404) max +455 °C (+850 °F)
➀
J 7 Bottom mount HT offset construction - 316/316L (1.4401/1.4404) max +455 °C (+850 °F)
➀
MOUNTING CONNECTION
0 0 00M
External mount Jupiter
NOTE: Magnetic Level Indicator (MLI) as shown on page 28 is not included in this partnumber
. For MLI ordering information,
consult sales bulletin 46-138
3/4" NPT M20 x 1,5 Cable entry (2 entries - one plugged)
1 2 G
eneral purpose (& I.S. - XP FM/CSA) Cast aluminium housing
3 4 General purpose (& I.S. - XP FM/CSA) Stainless steel housing
A B A
TEX II 1/2G EEx d IIC T6, explosion proof Cast aluminium housing
C D A
TEX II 1/2G EEx d IIC T6, explosion proof Stainless steel housing
E F ATEX II 1G EEx ia IIC T4, intrinsically safe Cast aluminium housing
G H ATEX II 1G EEx ia IIC T4, intrinsically safe Stainless steel housing
➀
With factory insulated MLI.
➀
L
evel and interface requires 2 floats, consult factory for MLI
PROBE LENGTH (specify in cm increments)
0 1 5 min 15 cm (6")
5
7 0 max 570 cm (224")
Refer to dimensions on the left page for proper probe length specification.